Under-tile floor heating
Warm tiles in bathrooms, kitchens and renovations. ELEKTRA DM20 cable sits in the self-leveller or screed under your tiles and runs room by room on a timer.
ELEKTRA DM20 heating cable.
A twin-conductor heating cable about 4 mm thick, made in Europe by ELEKTRA. It is laid at 100 mm spacing and connected through a factory-fitted cold tail to the thermostat. We select the length from your layout, so the cable is never cut on site.

From bare floor to warm tiles.



Everything else, when you need it.
Sizes, installation, running costs and common questions. Open any section.
All 21 DM20 sizesPart numbers, lengths, outputs
| Part no. | Length (m) | Output (W) | Approx. area (m²) | Current (A) |
|---|---|---|---|---|
| SIEDM125 | 6.5 | 125 | 0.7 | 0.5 |
| SIEDM195 | 10 | 195 | 1 | 0.8 |
| SIEDM215 | 11 | 215 | 1.1 | 0.9 |
| SIEDM280 | 14 | 280 | 1.4 | 1.2 |
| SIEDM325 | 16.5 | 325 | 1.7 | 1.4 |
| SIEDM365 | 18.5 | 365 | 1.9 | 1.5 |
| SIEDM420 | 21 | 420 | 2.1 | 1.8 |
| SIEDM470 | 23.5 | 470 | 2.4 | 2.0 |
| SIEDM600 | 29.5 | 600 | 3 | 2.5 |
| SIEDM660 | 33.5 | 660 | 3.4 | 2.8 |
| SIEDM820 | 40.5 | 820 | 4 | 3.4 |
| SIEDM1030 | 51 | 1,030 | 5.1 | 4.3 |
| SIEDM1150 | 58 | 1,150 | 5.8 | 4.8 |
| SIEDM1280 | 64 | 1,280 | 6.4 | 5.3 |
| SIEDM1440 | 73 | 1,440 | 7.3 | 6.0 |
| SIEDM1640 | 81 | 1,640 | 8.1 | 6.8 |
| SIEDM1940 | 98 | 1,940 | 9.8 | 8.1 |
| SIEDM2410 | 122 | 2,410 | 12.2 | 10.0 |
| SIEDM3000 | 150 | 3,000 | 15 | 12.5 |
| SIEDM3520 | 177 | 3,520 | 17.7 | 14.7 |
| SIEDM4050 | 205 | 4,050 | 20.5 | 16.9 |
Stocked range. Approximate area is at 100 mm cable spacing; your layout sets the exact cable. Current is calculated at 240 V.
Know the part numbers? Order any of these and send the list for trade pricing.
Order by part numberHeating mats, 12 sizes0.5 m wide mats
| Part no. | Mat size | Output (W) | Area (m²) |
|---|---|---|---|
| SIETXMD.5/2 | 0.5 x 2 m | 160 | 1 |
| SIETXMD.5/3 | 0.5 x 3 m | 240 | 1.5 |
| SIETXMD.5/4 | 0.5 x 4 m | 320 | 2 |
| SIETXMD.5/5 | 0.5 x 5 m | 400 | 2.5 |
| SIETXMD.5/6 | 0.5 x 6 m | 480 | 3 |
| SIETXMD.5/7 | 0.5 x 7 m | 560 | 3.5 |
| SIETXMD.5/8 | 0.5 x 8 m | 640 | 4 |
| SIETXMD.5/9 | 0.5 x 9 m | 720 | 4.5 |
| SIETXMD.5/10 | 0.5 x 10 m | 800 | 5 |
| SIETXMD.5/12 | 0.5 x 12 m | 960 | 6 |
| SIETXMD.5/14 | 0.5 x 14 m | 1,120 | 7 |
| SIETXMD.5/16 | 0.5 x 16 m | 1,280 | 8 |
Know the part numbers? Order any of these and send the list for trade pricing.
Order by part numberHeating mat kits, 8 sizesMat, HA308 thermostat and break alarm
| Part no. | Mat size | Output (W) | Kit includes |
|---|---|---|---|
| SIEKITXMD.5/2 | 0.5 x 2 m | 160 | Mat, HA308 thermostat, cable break alarm |
| SIEKITXMD.5/3 | 0.5 x 3 m | 240 | Mat, HA308 thermostat, cable break alarm |
| SIEKITXMD.5/4 | 0.5 x 4 m | 320 | Mat, HA308 thermostat, cable break alarm |
| SIEKITXMD.5/5 | 0.5 x 5 m | 400 | Mat, HA308 thermostat, cable break alarm |
| SIEKITXMD.5/6 | 0.5 x 6 m | 480 | Mat, HA308 thermostat, cable break alarm |
| SIEKITXMD.5/7 | 0.5 x 7 m | 560 | Mat, HA308 thermostat, cable break alarm |
| SIEKITXMD.5/8 | 0.5 x 8 m | 640 | Mat, HA308 thermostat, cable break alarm |
| SIEKITXMD.5/9 | 0.5 x 9 m | 720 | Mat, HA308 thermostat, cable break alarm |
Know the part numbers? Order any of these and send the list for trade pricing.
Order by part numberFixing and testing partsTape, fixing strip, break alarm
| Part no. | Description |
|---|---|
| SIETXXP5013 | Heating cable break alarm |
| SIETXXP5012 | Cloth fixing tape, 25 m x 48 mm |
| SIETXXP5014 | Fixing strip, 25 m roll |
Know the part numbers? Order any of these and send the list for trade pricing.
Order by part numberWhere it is used
- Bathrooms and ensuites. A warm tiled floor first thing in the morning, on a timer.
- Kitchens, laundries, entries and hallways. Tiled areas that are cold underfoot.
- Living areas being retiled. Over a slab or timber subfloor where in-slab is not an option.
- Whole-house renovations. Every tiled room on its own zone and thermostat.
- New builds alongside in-slab. In-slab through the living areas, under-tile in the bathrooms.
How it goes in
- Layout. Send the plan. We draw the cable layout, clear of vanities, toilets and cabinetry, with the zone load for your electrician. Within 24 hours, at no cost.
- Rough-in. The electrician runs a draw wire from the floor to the thermostat position before the walls are sheeted.
- Laying. After waterproofing, the cable is laid at 100 mm spacing and megger tested. A bathroom takes a couple of hours.
- Covering. The tiler covers the cable in self-leveller or sand-cement screed. Either is fine. Never tile adhesive.
- Tiling. Tiles go down as normal. The cable is megger tested before laying, after laying and after covering, with a break alarm on every job.
- Fit-off. After the floor coverings, the electrician fits the thermostat off like a normal power point. Circuit arrangement is the electrician’s call.
Running costs
An average bathroom of about 3 square metres uses roughly 600 W. At 27 cents per kWh that is about 16 cents per heating hour. Most owners run it for four to six hours a day in winter, which is about 65 cents to a dollar a day, and switch it off in summer.
Most people set the floor in the low 20s. Because under-tile heating warms up quickly, it only needs to run while the room is in use. The full working is in the running cost guide.
Thermostats and control
Every zone has its own thermostat with a floor sensor in a protective conduit in the screed. Programmable and Wi-Fi models are available. A bathroom is typically set for an hour in the morning and two or three hours in the evening. Thermostat warranty is one to three years, depending on the model.
See every model on the thermostats and controls page.
Floor coverings
DM20 suits tiled and stone floors over self-leveller or screed: porcelain, ceramic, natural stone and large-format tiles, over a concrete slab or timber subfloor. For engineered timber, vinyl and floating floors, ask before ordering. The answer depends on the flooring manufacturer’s rating.
Under-tile or in-slab?
Under-tile DM20 suits existing homes and renovations. Quick warm-up, room by room on a timer.
In-slab VCD35 suits new builds and extensions. Tied to the mesh at 200 mm centres before the pour for slow, even heat from the whole slab. See in-slab heating.
Loose cable or heating mats?
Mats are cable pre-fixed to a mesh. They are quick to lay in a plain rectangle and go down in tile adhesive. Loose DM20 is laid to the room, so it follows an L-shaped bathroom, goes around a fixed bath and stays clear of the vanity and toilet. It sits in self-leveller or screed. For most Australian bathrooms, loose cable gives a better fit. Not sure of the size? Try the cable selection tool.
Repairs
If a floor stops working, we carry a thermal imaging camera and fault-finding equipment to locate the exact spot. The repair is usually a small section of floor. We repair the ELEKTRA systems we supply. See floor heating repairs.
Common questions
Can under-tile heating go over a timber floor?
Yes. The cable is laid over the prepared subfloor and covered in self-leveller or screed by the tiler before tiling.
How thick is the floor build-up?
The cable is about 4 mm thick. The total height depends on the self-leveller or screed the tiler uses, and we can advise on the layout for tight door thresholds.
Does it go under the vanity and toilet?
No. Every layout keeps clear of vanities, toilets and cabinetry.
Can it go in the shower?
Yes, over the waterproofing, when the layout allows. The layout drawing shows exactly what is heated.
Can the cable be cut to fit?
No. We select the correct length from the layout. The heating cable is never cut or shortened on site.
Who connects it?
A licensed electrician fits the thermostat off and makes the final connection.
What is the warranty?
Twenty years on the DM20 cable. Thermostats carry a one to three year warranty, depending on the model.
Can my own electrician and tiler install it?
Yes. We supply the layout, cable, thermostat and floor sensor. The tiler covers the cable and a licensed electrician connects it.
Where do you supply?
Australia-wide, from stock, direct to site or to your electrician, and through electrical wholesalers.
Send your plans. Free layout within 24 hours.
Email info@papheatingsolutions.com.au or call (02) 6242 9310. We provide the layout design and load requirements at no cost.