Tiled bathroom with freestanding bath and under-tile floor heating
Applications · ELEKTRA DM20

Under-tile floor heating

Warm tiles in bathrooms, kitchens and renovations. ELEKTRA DM20 cable sits in the self-leveller or screed under your tiles and runs room by room on a timer.

20 Wper lineal metre
100 mmcable spacing
Self-leveller or screednever tile adhesive
21 sizes6.5 m to 205 m
20 yearscable warranty*
The product

ELEKTRA DM20 heating cable.

A twin-conductor heating cable about 4 mm thick, made in Europe by ELEKTRA. It is laid at 100 mm spacing and connected through a factory-fitted cold tail to the thermostat. We select the length from your layout, so the cable is never cut on site.

Output20 W per lineal metre
StandardsIEC 60800 and EN 60335-1
Test voltage2,500 V AC
Factory testEvery single cable, before it leaves the factory
JointsIPX7
Warranty20 years, conditions apply
Upload plans for a free layout
ELEKTRA DM20 heating cable and box
On site

From bare floor to warm tiles.

ELEKTRA DM20 cable laid over a waterproofing membrane in a bathroom
Cable laid over the waterproofing
ELEKTRA DM20 cable set out in an ensuite before the screed
Set out and tested before the screed
Finished tiled wet room with under-tile heating
Finished and tiled
Details

Everything else, when you need it.

Sizes, installation, running costs and common questions. Open any section.

All 21 DM20 sizesPart numbers, lengths, outputs
Part no.Length (m)Output (W)Approx. area (m²)Current (A)
SIEDM1256.51250.70.5
SIEDM1951019510.8
SIEDM215112151.10.9
SIEDM280142801.41.2
SIEDM32516.53251.71.4
SIEDM36518.53651.91.5
SIEDM420214202.11.8
SIEDM47023.54702.42.0
SIEDM60029.560032.5
SIEDM66033.56603.42.8
SIEDM82040.582043.4
SIEDM1030511,0305.14.3
SIEDM1150581,1505.84.8
SIEDM1280641,2806.45.3
SIEDM1440731,4407.36.0
SIEDM1640811,6408.16.8
SIEDM1940981,9409.88.1
SIEDM24101222,41012.210.0
SIEDM30001503,0001512.5
SIEDM35201773,52017.714.7
SIEDM40502054,05020.516.9

Stocked range. Approximate area is at 100 mm cable spacing; your layout sets the exact cable. Current is calculated at 240 V.

Know the part numbers? Order any of these and send the list for trade pricing.

Order by part number
Heating mats, 12 sizes0.5 m wide mats
Part no.Mat sizeOutput (W)Area (m²)
SIETXMD.5/20.5 x 2 m1601
SIETXMD.5/30.5 x 3 m2401.5
SIETXMD.5/40.5 x 4 m3202
SIETXMD.5/50.5 x 5 m4002.5
SIETXMD.5/60.5 x 6 m4803
SIETXMD.5/70.5 x 7 m5603.5
SIETXMD.5/80.5 x 8 m6404
SIETXMD.5/90.5 x 9 m7204.5
SIETXMD.5/100.5 x 10 m8005
SIETXMD.5/120.5 x 12 m9606
SIETXMD.5/140.5 x 14 m1,1207
SIETXMD.5/160.5 x 16 m1,2808

Know the part numbers? Order any of these and send the list for trade pricing.

Order by part number
Heating mat kits, 8 sizesMat, HA308 thermostat and break alarm
Part no.Mat sizeOutput (W)Kit includes
SIEKITXMD.5/20.5 x 2 m160Mat, HA308 thermostat, cable break alarm
SIEKITXMD.5/30.5 x 3 m240Mat, HA308 thermostat, cable break alarm
SIEKITXMD.5/40.5 x 4 m320Mat, HA308 thermostat, cable break alarm
SIEKITXMD.5/50.5 x 5 m400Mat, HA308 thermostat, cable break alarm
SIEKITXMD.5/60.5 x 6 m480Mat, HA308 thermostat, cable break alarm
SIEKITXMD.5/70.5 x 7 m560Mat, HA308 thermostat, cable break alarm
SIEKITXMD.5/80.5 x 8 m640Mat, HA308 thermostat, cable break alarm
SIEKITXMD.5/90.5 x 9 m720Mat, HA308 thermostat, cable break alarm

Know the part numbers? Order any of these and send the list for trade pricing.

Order by part number
Fixing and testing partsTape, fixing strip, break alarm
Part no.Description
SIETXXP5013Heating cable break alarm
SIETXXP5012Cloth fixing tape, 25 m x 48 mm
SIETXXP5014Fixing strip, 25 m roll

Know the part numbers? Order any of these and send the list for trade pricing.

Order by part number
Where it is used
  • Bathrooms and ensuites. A warm tiled floor first thing in the morning, on a timer.
  • Kitchens, laundries, entries and hallways. Tiled areas that are cold underfoot.
  • Living areas being retiled. Over a slab or timber subfloor where in-slab is not an option.
  • Whole-house renovations. Every tiled room on its own zone and thermostat.
  • New builds alongside in-slab. In-slab through the living areas, under-tile in the bathrooms.
How it goes in
  1. Layout. Send the plan. We draw the cable layout, clear of vanities, toilets and cabinetry, with the zone load for your electrician. Within 24 hours, at no cost.
  2. Rough-in. The electrician runs a draw wire from the floor to the thermostat position before the walls are sheeted.
  3. Laying. After waterproofing, the cable is laid at 100 mm spacing and megger tested. A bathroom takes a couple of hours.
  4. Covering. The tiler covers the cable in self-leveller or sand-cement screed. Either is fine. Never tile adhesive.
  5. Tiling. Tiles go down as normal. The cable is megger tested before laying, after laying and after covering, with a break alarm on every job.
  6. Fit-off. After the floor coverings, the electrician fits the thermostat off like a normal power point. Circuit arrangement is the electrician’s call.
Running costs

An average bathroom of about 3 square metres uses roughly 600 W. At 27 cents per kWh that is about 16 cents per heating hour. Most owners run it for four to six hours a day in winter, which is about 65 cents to a dollar a day, and switch it off in summer.

Most people set the floor in the low 20s. Because under-tile heating warms up quickly, it only needs to run while the room is in use. The full working is in the running cost guide.

Thermostats and control

Every zone has its own thermostat with a floor sensor in a protective conduit in the screed. Programmable and Wi-Fi models are available. A bathroom is typically set for an hour in the morning and two or three hours in the evening. Thermostat warranty is one to three years, depending on the model.

See every model on the thermostats and controls page.

Floor coverings

DM20 suits tiled and stone floors over self-leveller or screed: porcelain, ceramic, natural stone and large-format tiles, over a concrete slab or timber subfloor. For engineered timber, vinyl and floating floors, ask before ordering. The answer depends on the flooring manufacturer’s rating.

Under-tile or in-slab?

Under-tile DM20 suits existing homes and renovations. Quick warm-up, room by room on a timer.

In-slab VCD35 suits new builds and extensions. Tied to the mesh at 200 mm centres before the pour for slow, even heat from the whole slab. See in-slab heating.

Loose cable or heating mats?

Mats are cable pre-fixed to a mesh. They are quick to lay in a plain rectangle and go down in tile adhesive. Loose DM20 is laid to the room, so it follows an L-shaped bathroom, goes around a fixed bath and stays clear of the vanity and toilet. It sits in self-leveller or screed. For most Australian bathrooms, loose cable gives a better fit. Not sure of the size? Try the cable selection tool.

Repairs

If a floor stops working, we carry a thermal imaging camera and fault-finding equipment to locate the exact spot. The repair is usually a small section of floor. We repair the ELEKTRA systems we supply. See floor heating repairs.

Common questions

Can under-tile heating go over a timber floor?

Yes. The cable is laid over the prepared subfloor and covered in self-leveller or screed by the tiler before tiling.

How thick is the floor build-up?

The cable is about 4 mm thick. The total height depends on the self-leveller or screed the tiler uses, and we can advise on the layout for tight door thresholds.

Does it go under the vanity and toilet?

No. Every layout keeps clear of vanities, toilets and cabinetry.

Can it go in the shower?

Yes, over the waterproofing, when the layout allows. The layout drawing shows exactly what is heated.

Can the cable be cut to fit?

No. We select the correct length from the layout. The heating cable is never cut or shortened on site.

Who connects it?

A licensed electrician fits the thermostat off and makes the final connection.

What is the warranty?

Twenty years on the DM20 cable. Thermostats carry a one to three year warranty, depending on the model.

Can my own electrician and tiler install it?

Yes. We supply the layout, cable, thermostat and floor sensor. The tiler covers the cable and a licensed electrician connects it.

Where do you supply?

Australia-wide, from stock, direct to site or to your electrician, and through electrical wholesalers.

Get a layout

Send your plans. Free layout within 24 hours.

Email info@papheatingsolutions.com.au or call (02) 6242 9310. We provide the layout design and load requirements at no cost.